We have our own profits team, layout crew, technical team, QC team and package team. Now we have strict top quality handle procedures for each procedure. Also, all of our workers are experienced in printing industry for OEM/ODM Supplier Electric Heating Plate For University Laboratory, Adhering towards the enterprise philosophy of ‘customer very first, forge ahead’, we sincerely welcome shoppers from in your own home and abroad to cooperate with us.
We have our own profits team, layout crew, technical team, QC team and package team. Now we have strict top quality handle procedures for each procedure. Also, all of our workers are experienced in printing industry for Electric Heating Plate For Laboratory University Inspection Department, Electric Heating Plate For University Laboratory, High output volume, top quality, timely delivery and your satisfaction are guaranteed. We welcome all inquiries and comments. We also offer agency service—that act as the agent in china for our customers. If you are interested in any of our products or have an OEM order to fulfill, make sure you feel free to contact us now. Working with us will save you money and time.
Chemical composition:
Main and minor components | Min.content(%) | ASTM B386 (361) |
Mo | Balance | balance |
Ti | 0.40-0.55% | 0.40-0.55% |
Zr | 0.06-0.12% | 0.06-0.12% |
Impurities | Max.values (μg/g) | Max.values (μg/g) |
Al | 10 | - |
Cu | 20 | - |
Cr | 20 | - |
Fe | 20 | 100 |
K | 20 | - |
Ni | 10 | 50 |
Si | 20 | 100 |
W | 300 | - |
C | 100-400 | 100-400- |
H | 10 | - |
N | 10 | 20 |
O | 500 | 300 |
Cd | 5 | - |
Hg | 1 | - |
Pb | 5 | - |
Dimensions and tolerances:
Cold rolled sheets | |||
Thickness(mm) | Thickness tolerace(±mm) | Maximal width(mm) | Width tolerace(±mm) |
0.30-0.50 | 0.028 | 300 | 1.0 |
Hot rolled sheets | |||
Thickness(mm) | Thickness tolerace(±mm) | Maximal width(mm) | Width tolerace(±mm) |
0.50-0.60 | 0.06 | 850 | 1.6 |
0.60-1.00 | 0.08 | 850 | 1.6 |
1.00-1.50 | 0.13 | 850 | 2.0 |
1.50-2.00 | 0.15 | 850 | 2.0 |
2.00-3.60 | 0.18 | 850 | 2.0 |
3.60-50.0 | 5% | 1000 | 2.0 |
Length tolerance:
The length tolerance for all dimension is maximal +5/-0 mm.
Flatness: max. 4 % (measuring procedure on the basis of ASTM B 386)
Density: ≥ 10.1 g/cm³
Vickers Hardness: 220-320 HV
Tensile Test:
Thickness (mm) | Tensile StrengthMin. (MPa) | 0.2% Yield strengtMin.(MPa) | ElongationMin.(%) |
0.30-1.00 | 700 | 600 | 5 |
1.00-2.50 | 700 | 600 | 10 |
2.50-5.00 | 700 | 600 | 12 |
5.00-20.00 | 650 | 600 | 10 |
20.00-50.00 | 550 | 470 | 5 |
Appearance: The material will be of uniform quality, free from foreign mater, splits and fractures. Bed sheet (not trimmed) may have small edge cracks.
Surface defedts are assessed in the frame of visual inspection.
Surface condition: pickled.